HVAC, test & balance and electrical calcs with project records and PDF reports
E+HVAC is a professional field app for HVAC and mechanical engineers, TAB (Testing, Adjusting & Balancing) technicians and electrical engineers. Run your calculations, record readings by project and create a professional PDF report in one tap. No internet required — it works in basements, on roofs, anywhere on site.
■ TEST & BALANCE (TAB)
• Project → Equipment (AHU, fans, fan coils, VAV, heat recovery, pumps…) → Outlets
• Design vs measured airflow and % of design — color-coded by tolerance band (green / amber / red)
• Outlet airflow from flow hood readings or Ak factor × average velocity
• "Save & next" for fast entry: tags auto-increment (S-01 → S-02)
• Supply / return / exhaust / outdoor air totals
• Duct traverses — ASHRAE log-Tchebycheff point layouts (distances from wall in mm), velocity or pitot velocity pressure (Pv) input
• Water-side balancing valves — flow from Kv + measured ΔP or instrument reading, totals and tolerance check
• Photos from camera / gallery on equipment, outlets and valves (nameplates, dampers, valve settings…)
• Motor readings: voltage, L1-L2-L3 current, current unbalance, load %, speed, VFD frequency
• Adjustable tolerance band (default ±10 %)
■ PDF REPORT
• TAB report with your company header, page numbers and signature blocks
• Project info, instruments used, equipment summary, outlet tables, traverses and saved calculations
• Print or share by e-mail / messaging apps (A4 / Letter)
• Excel (.xlsx) export: summary, outlets, valves, traverses and motor readings on separate sheets; plus CSV
■ 39 CALCULATIONS
Air side: airflow from velocity, velocity from airflow, duct sizing (velocity and equal friction), duct pressure loss (Colebrook + fittings), rectangular → equivalent diameter (Huebscher), velocity pressure, fan power, fan laws, mixed air, outdoor air % from temperatures, air changes per hour, Ak factor
Heat & psychrometrics: sensible, latent and total heat, psychrometrics (wet bulb, dew point, enthalpy, humidity ratio), coil load and SHR, capacity conversion (kW / Btu/h / tons / kcal/h), quick cooling load estimate
Water side: water flow from load (water / glycol), load from water flow, pipe sizing and pipe pressure drop (steel, copper EN 1057, PPR, PEX tables), pump power, pump affinity laws, Kv / Cv, expansion tank
Electrical: Ohm's law, single and three-phase power, current from power, motor full-load and starting current, voltage drop, cable size by voltage drop, power factor correction (kVAr), kVA → current, conductor resistance, energy cost
Every calculation shows its formula and source (ASHRAE, SMACNA, IEC 60364, EN 12828…). Copy results or save them to a project.
■ PROFESSIONAL DETAILS
• SI ⇄ IP units in one tap (m³/h ⇄ CFM, Pa ⇄ in.wg, kW ⇄ Btu/h, °C ⇄ °F…)
• Unit converter
• English and Turkish interface
• Light / dark theme
• Favorite calculations and quick search
■ YOUR DATA STAYS WITH YOU
• All data is stored only on your device; no account needed
• No personal data collected, no ads
• Back up everything, photos included, to one .zip file and move to a new phone
Note: E+HVAC is intended for reference and field use; it does not replace detailed design, manufacturer data or the judgement of a qualified engineer.