# Grounding Size Calc NEC

> NEC Art.250 EGC & GEC

Canonical page: [https://chrome-stats.com/d/id6763312724](https://chrome-stats.com/d/id6763312724)

## Overview

- **ID:** `id6763312724`
- **Platform:** Apple
- **Type:** Apple app
- **Status:** Available
- **Publisher:** Rizvan Adzhoian
- **Category:** Utilities
- **Version:** 1.0.8
- **Last updated:** 2026-06-10
- **First published:** 2026-04-24
- **Size:** 34 MB
- **Data as of:** 2026-09-25
- **Store listing:** [Apple App Store](https://apps.apple.com/us/app/grounding-size-calc-nec/id6763312724)
- **Website:** [https://tradetools.dev/](https://tradetools.dev/)
- **Privacy policy:** [https://tradetools.dev/privacy-policy.html](https://tradetools.dev/privacy-policy.html)

## Description

Grounding Size Calc NEC - professional NEC calculator for electricians. Offline, permit-ready.

NEC grounding size calculator for electricians, apprentices, and electrical engineers. Three calculators in one app: Equipment Grounding Conductor (EGC) from Table 250.122, Grounding Electrode Conductor (GEC) from Table 250.66 with sole-connection exceptions, and Bonding Jumper from Table 250.102(C)(1) with the 12.5% rule. Works 100% offline on the job site.

Whether you're sizing an EGC for a 200A circuit, determining the GEC for a 500 kcmil service with a ground rod electrode, or calculating a bonding jumper for parallel service conductors, this calculator gives you accurate NEC-compliant results in seconds.

THREE CALCULATORS IN ONE:

EQUIPMENT GROUNDING CONDUCTOR (EGC):
- Size EGC per NEC Table 250.122 - all 21 table rows from 15A to 6000A
- All 37 standard OCPD ratings per NEC 240.6(A) selectable - including 30A, 40A, 50A, 70A, 125A
- Copper and aluminum conductor support
- Voltage drop adjustment per NEC 250.122(B) - proportionally increase EGC when circuit conductors are upsized
- Original and adjusted wire size selection for accurate proportional calculation
- Automatic rounding up to next standard OCPD rating

GROUNDING ELECTRODE CONDUCTOR (GEC):
- Size GEC per NEC Table 250.66 based on service conductor size
- Support for copper and aluminum service conductors
- Parallel sets calculation (1-6 sets) with automatic equivalent area computation
- Sole-connection exceptions per NEC 250.66(A), (B), and (C):
  - 250.66(A): Rod, pipe, or plate electrode - GEC capped at #6 Cu / #4 Al
  - 250.66(B): Concrete-encased electrode - GEC capped at #4 Cu / #4 Al
  - 250.66(C): Ground ring - GEC capped at #2 Cu / #2 Al
- Five electrode types: Water Pipe, Rod/Pipe/Plate, Concrete-Encased, Ground Ring, Other

BONDING JUMPER:
- Size bonding jumpers per NEC Table 250.102(C)(1)
- Same ranges as Table 250.66 for conductors within table limits
- Automatic 12.5% rule for service conductors exceeding 1100 kcmil Cu or 1750 kcmil Al
- Parallel sets support with combined circular mil area calculation

CALCULATION RESULTS INCLUDE:
- Conductor size in AWG or kcmil with alternative material
- Exception applied with NEC section reference
- NEC article references for every result
- Detailed notes for parallel sets and electrode exceptions

NEC REFERENCES INCLUDED:
- NEC Table 250.122 - Equipment grounding conductor sizing
- NEC 250.122(B) - EGC increase for voltage drop
- NEC Table 250.66 - Grounding electrode conductor sizing
- NEC 250.66(A) - Rod, pipe, or plate electrode exception
- NEC 250.66(B) - Concrete-encased electrode exception
- NEC 250.66(C) - Ground ring exception
- NEC Table 250.102(C)(1) - Bonding jumper sizing
- NEC 250.102(C)(1) - 12.5% rule for large conductors

PRO FEATURES (one-time purchase):
- No ads - clean interface for professionals
- Save grounding calculation history with labels
- Export calculations as PDF reports for permits and records
- Dark theme support

PERFECT FOR:
- Licensed electricians sizing grounding conductors daily
- Electrical apprentices and journeyman exam preparation
- Electrical engineers specifying grounding systems
- Electrical inspectors verifying conductor sizes

OFFLINE & PRIVACY:
- Works 100% offline - no internet needed on the job site
- No account required
- No data collection - your calculations stay on your device

Simplify your grounding and bonding calculations on the job site.

## Rankings

- #1,109,502 — Overall

## Similar extensions and apps

- [QuickNEC: NEC Calculator](https://chrome-stats.com/d/id6758503497) — 1.00 / 5
- [ElectricianCalc NEC Calculator](https://chrome-stats.com/d/id6763315320) — 5.00 / 5
- [NEC Electrician Calc: VoltKit](https://chrome-stats.com/d/id6782881081)
- [Electrical Calculator ElecCalc](https://chrome-stats.com/d/id6758902534)
- [NG Wire: NEC Ampacity & Fill](https://chrome-stats.com/d/id6478354523) — 5.00 / 5
- [Voltkit: NEC Conduit Fill Calc](https://chrome-stats.com/d/id6783893946)
- [Electric Master: NEC Panel](https://chrome-stats.com/d/id6760935722) — 3.60 / 5
- [Sparky's Black Book](https://chrome-stats.com/d/id6770407622) — 5.00 / 5
- [NEC Box & Conduit Calc](https://chrome-stats.com/d/id6755513987) — 4.90 / 5
- [Electrical Calculator: NEC](https://chrome-stats.com/d/id6781034650)
- [NEC Box Fill Calc](https://chrome-stats.com/d/id6767993285)
- [Master Electrician License Ex](https://chrome-stats.com/d/id6763056723)

---

Source: [Chrome-Stats](https://chrome-stats.com/d/id6763312724)