# PLC-Inspector

> Modbus/TCP for Siemens LOGO!

Canonical page: [https://chrome-stats.com/d/id6756433005](https://chrome-stats.com/d/id6756433005)

## Overview

- **ID:** `id6756433005`
- **Platform:** Apple
- **Type:** Apple app
- **Status:** Available
- **Publisher:** spiritdev Softwareentwicklung GmbH
- **Category:** Utilities
- **Version:** 1.2
- **Last updated:** 2026-09-03
- **First published:** 2026-01-26
- **Size:** 4.13 MB
- **Data as of:** 2026-09-18
- **Store listing:** [Apple App Store](https://apps.apple.com/us/app/plc-inspector/id6756433005)
- **Website:** [https://plc-inspector.com](https://plc-inspector.com/)
- **Privacy policy:** [https://plc-inspector.com/legal/privacy-en.html](https://plc-inspector.com/legal/privacy-en.html)

## Description

PLC-Inspector is a professional diagnostic tool for Siemens LOGO! controllers. Read memory, follow changes live and set registers, over Modbus/TCP, directly from iPhone, iPad or Mac.

KEY FEATURES

• Memory reading
VM memory, analog inputs (AI) and analog outputs (AQ) of your LOGO! in real time.

• Register writing
Enter values in decimal or hexadecimal and send them to the controller. The app checks what the controller reports back and says so separately when the confirmation does not match the request.

• Safeguarded writing
Write mode has to be switched on deliberately and expires when you leave the view. Before every write there is a confirmation showing register and value in plain text, which can be switched off for a working session.

• Bit-level visualisation
Every register as a 16-bit value with colour-coded bit display.

• Change detection
Changed values are highlighted in orange. Jump between changes with the arrow buttons.

• Auto-refresh
Automatic updates in intervals from 0.5 to 10 seconds.

• Multiple stations
Manage any number of PLC stations with individual settings.

APPLICATIONS

- Commissioning and fault finding on site
- Mobile process monitoring
- Analysis of memory contents
- Training and education

TECHNICAL DETAILS

- Protocol: Modbus/TCP (default port 502)
- Reading: Read Holding Registers (FC 03), automatic splitting above 125 registers
- Writing: Write Single Register (FC 06) with echo verification
- Supported controller: Siemens LOGO! 8 (0BA8)

NOTE
The app needs a network connection to the LOGO! controller. The Modbus server must be enabled in LOGO!Soft Comfort.

Developed by spiritdev Softwareentwicklung GmbH - your partner for industrial software solutions.

## Rankings

- #1,224,440 — Overall

## Similar extensions and apps

- [PLC Controller & Simulator](https://chrome-stats.com/d/id6785697528)
- [FA Labo PLC Console](https://chrome-stats.com/d/id6783619471)
- [PieeerU](https://chrome-stats.com/d/id6769785505)
- [LineKeeper](https://chrome-stats.com/d/id6791371574)
- [S7 PLC HMI](https://chrome-stats.com/d/id6801989589)
- [PLC Tools Plus](https://chrome-stats.com/d/id6798494965)
- [IO-Inspector](https://chrome-stats.com/d/id6758009180)
- [PlcConsole](https://chrome-stats.com/d/id6787385894)
- [Modbus TCP Pro](https://chrome-stats.com/d/id6756293575)
- [PLC Pro](https://chrome-stats.com/d/id6757437125)
- [Plc Echo](https://chrome-stats.com/d/id6738625340)
- [Modbus 40001](https://chrome-stats.com/d/id6799202584)

---

Source: [Chrome-Stats](https://chrome-stats.com/d/id6756433005)
