# InstElectric Pro - Electricity

> Electrical installations

Canonical page: [https://chrome-stats.com/d/id1447888290](https://chrome-stats.com/d/id1447888290)

## Overview

- **ID:** `id1447888290`
- **Platform:** Apple
- **Type:** Apple app
- **Status:** Removed
- **Publisher:** Angel Martinez
- **Category:** Productivity
- **Rating:** 4.50 / 5 (17 ratings)
- **Version:** 3.0.2
- **Last updated:** 2026-01-22
- **First published:** 2019-01-04
- **Size:** 15 MB
- **Data as of:** 2026-07-25
- **Store listing:** [Apple App Store](https://apps.apple.com/es/app/instelectric-pro-electricity/id1447888290?l=en-GB)
- **Website:** [https://electricalsoft.com](https://electricalsoft.com/)
- **Privacy policy:** [https://drive.google.com/open?id=1bWX6fx2E0WsYiPGlg9CuvA4XrRjGA9\_g](https://drive.google.com/open?id=1bWX6fx2E0WsYiPGlg9CuvA4XrRjGA9_g)

## Description

Tool to support the calculation of electrical installations that will allow the user (designer/electrician/technician) to perform electrical calculations easily and quickly.

· Dimensioning complete of low voltage circuits with the most frequent installation methods
· Phase cable size, neutral, protective conductor
· Criteria based on the admissible current of the cable, voltage drop and overcurrent protection
· Designation of the most used cables.
· Circuits with automatic circuit breaker until In=4000 A (Ir rating setting), maximum fuse In=1600 A (gG type), maximum 12 conductors parallel per phase, maximum size 630 mm²
· Short-circuits, including MV network, LV lines and final circuit
· Estimate of the maximum short-circuit current (simplified method)
· Maximum protected length for minimum short circuit (approximate method)
· Earthing system with diferentes types of electrodes (rods, buried conductor, rings and grid)
· Distance between the earthing systems
· Forecast of loads of a building destined to houses with several sections: dwellings, common services, commercial premises/offices and garage with/without infrastructure for recharging electric vehicles
· Reactive power of the capacitor bank for the compensation of the power factor (cos φ) and capacity (µF) of the capacitors
· C/K Factor for automatic capacitor bank
· Frequency resonance capacitors
· Compensation of the power factor for a three-phase transformer
· Choice of installation system in the function of the circuit, cable and its situation
· Overvoltage due to defects to earth in medium voltage MV depending on the earthing systems
· Power in an unbalanced three-phase system
· Overvoltages due to loss of neutral conductor, earth fault and short circuit
· Electricity parameters of a single-phase or three-phase (balanced)
· Transformer performance
· Secondary voltage of a transformer acoording to switch position
· Distribution of load of transformers in parallel
· K-Factor transformer
· Current transformer
· Verification resistance of the assembly to short-circuits
· Dissipated power of a assembly
· Size of trays and conduits
· Conduits characteristics according to the installation method
· Conversions of wire sizes (mm²-awg) and conduits threads
· Impedance, resistance and reactance of a cable
· Representation of the curves of the protections
· International protection IP - IK

Parameter settings for calculations:
· Constants (voltages, conductivity, temperatures, etc.) that affect electrical calculations
· Protections (circuit breakers and fuses)
· Selection of minimum rate for circuit-breakers with regulation and maximum cable size for multi-conductor grouping per phase
· Method estimation of the reactance
· Conductivity of the conductor depending on the current of the circuit (constant, according to the expected current, maximum cable temperature)
· Use reduction factors by grouping cables/circuits
· Use of factors of diversity/utilization

· Reference documents: IEC Standards, REBT (sp), Technical Application Guide, (UE) 2016/364

IN NO CASE SHALL THE AUTHOR BE LIABLE FOR ANY DIRECT OR INDIRECT DAMAGES AS A RESULT OF THE CORRECT OR INCORRECT USE OF THE APPLICATION

## Similar extensions and apps

- [Ampère Mobile](https://chrome-stats.com/d/id672293934) — 5.00 / 5
- [ElectricCalc Pro](https://chrome-stats.com/d/id6740990826)
- [ElectriCalc: Engineering Tool](https://chrome-stats.com/d/id6762361122)
- [Electrical Calculator Pro](https://chrome-stats.com/d/id6759329271)
- [Electrical Calculations](https://chrome-stats.com/d/id993232048) — 4.60 / 5
- [Medium Voltage Calculations](https://chrome-stats.com/d/id1559657607)
- [ElectriCalc: Electrician Calc](https://chrome-stats.com/d/id6788265522)
- [The Electrician Tools](https://chrome-stats.com/d/id6756527396)
- [Electrician Calculator Pro 26](https://chrome-stats.com/d/id6773967961)
- [EV Calc Pro](https://chrome-stats.com/d/id6760562066) — 5.00 / 5
- [Electrical Calculator ElecCalc](https://chrome-stats.com/d/id6758902534)
- [Electrician's assistant](https://chrome-stats.com/d/id6740750504)

---

Source: [Chrome-Stats](https://chrome-stats.com/d/id1447888290)