# Flowforge: Fire Sprinkler Kit

> Sprinkler fitter calculators: K-factor, friction loss, flow test, NFPA 25 ITM.

Canonical page: [https://chrome-stats.com/d/com.tapforgestudios.flowforge](https://chrome-stats.com/d/com.tapforgestudios.flowforge)

## Overview

- **ID:** `com.tapforgestudios.flowforge`
- **Platform:** Android
- **Type:** Android app
- **Status:** Available
- **Publisher:** TapForge Studios
- **Category:** PRODUCTIVITY
- **Downloads:** 5
- **Version:** 1.0.2
- **Last updated:** 2026-09-07
- **First published:** 2026-07-21
- **Publisher country:** US
- **Size:** 27 MB
- **Data as of:** 2026-09-18
- **Store listing:** [Google Play Store](https://play.google.com/store/apps/details?id=com.tapforgestudios.flowforge)
- **Website:** [http://Tapforgeapps.com](http://tapforgeapps.com/)
- **Privacy policy:** [https://tapforgeapps.com/uploads/flowforge-fire-sprinkler-kit-privacy-f69bdebf.html](https://tapforgeapps.com/uploads/flowforge-fire-sprinkler-kit-privacy-f69bdebf.html)

## Description

Flowforge puts a sprinkler fitter&#39;s daily math and reference tables in one fast, offline app. Built by a life-safety trades background, not a software company guessing at what the field needs.<br><br>HYDRAULICS<br>• K-Factor Flow — Q = K√P, solve for flow, pressure, or K<br>• Friction Loss — Hazen-Williams with real Sch 40 / Sch 10 / copper / CPVC pipe IDs<br>• Flow Test Analysis — project available gpm at 20 psi from static, residual, and test flow (Pro)<br>• Pitot Flow — outlet flow from pitot pressure and coefficient<br>• Pipe Volume — gallons per run with a running system total (Pro)<br>• Water Velocity and Elevation ↔ Pressure converters<br><br>SPACING &amp; LAYOUT<br>• Sprinkler Spacing — max coverage and spacing by hazard and construction<br>• Hanger Spacing — steel, lightwall, copper, and CPVC tables<br>• Trapeze Sizing — section modulus from span and load, with the member picked for you (Pro)<br>• Obstructions — beam rule and three-times rule calculators (Pro)<br>• Deflector Position — distance below ceiling and storage clearance checks (Pro)<br><br>SYSTEMS &amp; TESTING (Pro)<br>• Dry System Air — air pressure from supply static and valve ratio<br>• Pipe Pitch — drop over run for drainage<br>• Fire Pump Check — churn / 100% / 150% test points against the rated curve<br>• Standpipe Demand — Class I–III flow and pressure<br>• Main Drain Test — compare against baseline with the 10% rule<br>• Hydrostatic Test — required pressure and duration<br><br>REFERENCE<br>• K-Factor Chart — orifice sizes, threads, % of K5.6<br>• Temperature Ratings — classifications with glass bulb colors and frame colors<br>• NFPA 25 ITM — searchable inspection, testing, and maintenance frequencies (Pro)<br>• Pipe Data — OD, ID, gallons per foot, water-filled weight<br>• Fitting Equivalent Lengths — C=120 table with C-factor adjustments (Pro)<br>• Hazard Classifications, System Types, and every formula on one card<br><br>FREE VS PRO<br>12 tools are free forever, with a small banner ad. One inexpensive one-time purchase unlocks all 26 tools and removes ads permanently. No subscription. No account. No sign-in.<br><br>BUILT FOR THE FIELD<br>• Works 100% offline — riser rooms and basements have no bars<br>• Dark interface built for dim mechanical rooms<br>• Monospace results you can read at arm&#39;s length<br><br>Flowforge is a field reference, not an engineering authority. Always verify results against the adopted NFPA edition, product listings, approved drawings, and your AHJ.<br><br>From TapForge Studios — the maker of Pipeforge, Voltbox, Airforge, and Fireforge. Trade tools by the trades.

## Rankings

- #2,961,696 — Overall

## Permissions and access

### Permissions

- `android.permission.ACCESS_ADSERVICES_AD_ID`
- `android.permission.ACCESS_ADSERVICES_ATTRIBUTION`
- `android.permission.ACCESS_ADSERVICES_TOPICS`
- `android.permission.ACCESS_NETWORK_STATE`
- `android.permission.FOREGROUND_SERVICE`
- `android.permission.INTERNET`
- `android.permission.WAKE_LOCK`
- `com.android.vending.BILLING`
- `com.google.android.gms.permission.AD_ID`
- `com.tapforgestudios.flowforge.DYNAMIC_RECEIVER_NOT_EXPORTED_PERMISSION`

## Similar extensions and apps

- [Fire Sprinkler design tools](https://chrome-stats.com/d/com.pocketengineer.aSprinkler) — 166 users
- [Fire Sprinkler Tools](https://chrome-stats.com/d/com.qr3.fst)
- [FireSprinkPro Design Studio](https://chrome-stats.com/d/com.fireandflow.hydrauliccalculator) — 23 users
- [FireCalc Pro –AS Fire Standard](https://chrome-stats.com/d/com.mankoulah.firecalc)
- [Hydrant Flow Test Calculator](https://chrome-stats.com/d/com.at.hydrantflowtest.calculator) — 182 users
- [Pipeforge: Plumbing Tools](https://chrome-stats.com/d/com.tapforgestudios.pipeforge) — 11 users
- [FireFlow](https://chrome-stats.com/d/au.com.digigorcka.www.fireflow) — 228 users
- [HydroPortable](https://chrome-stats.com/d/com.idraulica.hydroportablesuite)
- [Sprinkler Fitter Calculator](https://chrome-stats.com/d/com.igneusinc.SFC) — 28 users
- [QuicKalc Fire Sprinkler Hardy-](https://chrome-stats.com/d/quicKalc_V1.quicKalc_V1) — 156 users
- [HydroFlow](https://chrome-stats.com/d/com.alexorange.hydrocalc) — 34 users
- [HydroCalc Plus](https://chrome-stats.com/d/com.alexesc.headlossplus) — 91 users

---

Source: [Chrome-Stats](https://chrome-stats.com/d/com.tapforgestudios.flowforge)
